OSHA Provides Technical Amendment to General Industry Rule on Walking-Working Surfaces and Personal Protective Equipment Standards

Jul 06, 2017

Effective July 6, 2017

OSHA has provided a technical amendment to the recently published General Industry rule on Walking-Working Surfaces and Personal Protective Equipment (Fall Protection Systems) standards.

Supplementary Information

Final 29 CFR 1910 General Industry Standards subpart D contains three new collections of information. 

First, final § 1910.23(b)(10) requires that employers ensure any ladder with structural or other defects be tagged immediately with “Dangerous: Do Not Use” or similar language and removed from service until “repaired . . . or replaced.” The information will alert employers and workers that the ladder is not safe and must not be used.

Second, final § 1910.27(b)(1)(i) requires, before any rope descent system is used, that the building owner inform the employer in writing that the building owner has identified, tested, certified, and maintained each anchorage so it is capable of supporting at least 5,000 pounds (268 kg), in any direction for each employee attached. The information must be based on an annual inspection by a qualified person and certification of each anchorage by a qualified person, as necessary, and at least every 10 years. The information will assure employers and workers that the building owner has inspected, tested and certified the anchorage, which the employer may not own or have any control over, as safe to use. A related provision, final § 1910.27(b)(1)(ii), requires that the employer ensure no employee uses any anchorage before the employer has obtained written information from the building owner indicating that each anchorage meets the requirements of § 1910.27(b)(1)(i). The employer must keep the information for the duration of the job. The information will assure employers and workers that the anchorages employers use, but may not own or have any control over, are safe to use. 

Third, final § 1910.28(b)(1)(ii) specifies that when employers can demonstrate that it is not feasible or creates a greater hazard to use guardrail, safety net, or personal fall protection systems on residential roofs, they must develop and implement a written fall protection plan that meets the requirements of 29 CFR 1926.502(k) and training that meets the requirements of 29 CFR 1926.503(a) and (c). The information collection ensures that employers and workers will know what alternative measures will be used at a given worksite to provide an appropriate level of protection when conventional fall protection is not feasible.

  • View a complete listing of NECA's resources and industry information by topic.
  • NECA’s education programs provide innovation, business trends and effective leadership exclusive to electrical contractors.
  • NECA is working every day to ensure you have every opportunity available to stay on top of the issues affecting your business and to be directly in touch with your Senators and your Representative in Congress.
  • NECA communities are member-initiated groups where contractors and industry professionals sharing common interests and business concerns can come together.
  • NECA membership isn’t just about saving your firm time and money; it’s also about helping your company make more money and achieve success!
  • NECA contractors employ the most highly trained and reliable workforce in the industry. They will get your job done right the first time, on time, without disrupting your business.